CS448 Isolated Oscilloscope | Cleverscope Mixed Signal USB Oscilloscopes (2024)

The CS448 is a 1kV isolated channel oscilloscope designed to be useful anywhere isolation is needed - in particular power electronics. The CS448 supports - via the Cscope4 application- Frequency Response Analysis (using the built in isolated signal generator), Protocol decoding, Maths, streaming, Excel and Matlab connectivity, Spectrum Analysis, mixed signal triggering and display.

The high channel common mode rejection ratio (100 dB at 50 MHz) means the CS448 can be used to measure signals such as gate drives and current sensors whose common mode is slewing quickly.

The CS448 comes complete with:
4 off 1x/10x (8/80V) 250 Mhz probes
4 off 100x (800V) 250MHz MHz probes. If you wish these can be swapped for 200 x probes (1600V 350MHz)
4 off Scope probe cable Common mode chokes to reduce high edge rate ring.
2 off isolated digital channel pods (Chan 1-4 + Chan 5-8).
Power Supply + IEC cable for your country
USB3 cable
SMA - BNC adaptor for signal generator.
SFP module for Ethernet - choose optical or copper
CD with application, data sheet and user manual. Drivers coming soon.
Install app note.

You might also like to check out the CS1110 VceSat Probe and the CS1070 Power amplifier to increase the versatility of the system.

Parameter

Specification

Notes

Analog Bandwidth

200MHz


Number of channels

4


Isolation Voltage

1kV working

Supported by IEC 61010-1 creepage and clearance, reinforced, Category III and 1.5kV Class II.

Plan to certify

CMRR

> 120 dB at 1 MHz

> 115 dB at 10 MHz

> 100 dB at 50 MHz

Done using a 20 dBV test source

ADC resolution

14 bits


Input Ranges

±0.8V and ±8V

Use probes to extend the range, eg 800V with 100x probe. The application automatically scales all values to compensate for probe attenuation.

Sample Rate

400 MSPS

All Analog and Digital channels simultaneously. 500 MSPS later.

Sample Memory

250 M Samples

For a single channel. For four channels = 62.5 Msamples (125 msecs at full rate). Currently max 10 MSamples.

CM leakage to other channels

<-125dBc

20 dBV signal to CM channel, measured on other channels whole bandwidth, ±0.8V range

Channel to Channel Skew

< ±144ps

Done using a 1 MHz coherent sine wave

Cross talk at 10.7 and 30 MHz

< -115 dBc

Using 1.6V p-p into the channel

RMS Channel Noise 1 M samples

< 210 uV rms, ±0.8V range

< 2.1mv rms, ±8V range

Inputs open

Pk-Pk Channel noise 1 M samples

1.8mVp-p for ±0.8V range

15mVp-p for ±8V range

Inputs open

Sample clock jitter

300 fs rms


Sample clock absolute Freq accuracy

±2 ppm

At 23 deg C

Sample clock temp stability

±0.5 ppm

Over -40 to +85 deg C

Enob (rms)

11.6 bits, or 1 part in 3,300

Inputs open

Noise free bits

10.3 bits, or 1 part in 1300

Inputs open

Spectral Noise floor,

no protrusions

-100 dBV

-115dBV

<2MHz, 200 MHz BW, 1kHz resolution

>2MHz, 200 MHz BW, 1kHz resolution

Sinad

> 64 dBc at 1 MHz

> 63 dBc at 10 MHz

> 55 dBc at 30 MHz

1 Vp-p into 50 ohms signal

HD2+3

< -80dB at 1MHz

< -76 dB at 10 MHz

< -71 dB at 30 MHz

1 Vp-p into 50 ohms signal

THD

< -76 dB at 1 MHz

< -74 dB at 10 MHz

< -67 dB at 30 MHz

1 Vp-p into 50 ohms signal

Pulse Flatness

< 700uV

< 2mV

< 1V

0.5V pulse, 500us duration, ±0.8V range

0.5V pulse, 500 us duration, ±8V range

500V pulse, 500us duration, 100x probe

Overload recovery

4ns

Recovery from 10x overload

Maximum Differential Input Voltage

±1 kV, derated above 1 MHz.

Derated at 20dB/decade

Maximum Common Mode Input Voltage

±1 kV, derated above 10 MHz.

Derated at 20dB/decade

Spectral Flatness

±0.2dB from 0 - 160 MHz

-2 dB at 200 MHz

Supports 200 MHz Bandwidth

Input Resistance

1 M Ohm

DC resistance

Input Capacitance

20 pF

Signal Input to Signal Common

Isolation Capacitance

< 14pf

Channel ground to chassis

Isolation Capacitance

< 6pf

Channel to channel

The Link Port is used for controllingCleverscope accessory devices such as the CS1070 1A 50 MHz power amplifier, andthe CS1110 VCE Sat Probe. It also includes RS232, SPI and I2Cports for controlling user equipment.

The Link In/Out Port is used daisy chaining2 or more CS448 Cleverscopes.

CS448 Isolated Oscilloscope | Cleverscope Mixed Signal USB Oscilloscopes (2024)
Top Articles
Latest Posts
Article information

Author: Nathanial Hackett

Last Updated:

Views: 5729

Rating: 4.1 / 5 (52 voted)

Reviews: 91% of readers found this page helpful

Author information

Name: Nathanial Hackett

Birthday: 1997-10-09

Address: Apt. 935 264 Abshire Canyon, South Nerissachester, NM 01800

Phone: +9752624861224

Job: Forward Technology Assistant

Hobby: Listening to music, Shopping, Vacation, Baton twirling, Flower arranging, Blacksmithing, Do it yourself

Introduction: My name is Nathanial Hackett, I am a lovely, curious, smiling, lively, thoughtful, courageous, lively person who loves writing and wants to share my knowledge and understanding with you.